Fire Alarm System
-
The CSP fire alarm system is a state-of-the-art equipment to be installed in smaller facilities which requires an exclusive alarm system.
-
It is managed by CSP fire alarm control panels (FACP) with an easy to read front panel for convenient system operation.
-
The alarms can be used in small hotels, guest houses, kindergartens, bank branches, museums etc.
-
It is also ideal in single rooms such as locker rooms, storerooms and server rooms.
-
The CSP is conventional because of its low maintenance and installation cost.
-
The SSP Fire Detection and Alarm System (FDAS) meets the strict EN54 safety standards.
-
SATEL control panels are an uncomplicated installation, their aesthetic appearance and the use of a single, standard 12 V battery as a backup power supply source.
Smoke and Heat Multi-Sensor Detector
-
The point multi-sensor detector combines in a single device visible smoke detection, the rate-of-rise detection and the detection of cases of exceeding the limit temperature. Owing to this combination of detection technologies, the DMP-100 detector can detect many different sources of fire.
-
unique Swirl chamber accelerates smoke detection
-
test fires detected: TF-1 to TF-5 acc. to EN54-7 and TF-1, TF-6 and TF-8 acc. to ISO/TS 7240-9:2006
-
A1R heat detector in conformance with EN54-5
-
stainless-steel precision filter
-
simple detector installation at the base of DB-100
-
possibility of connecting an external status indicator
-
Dust and dirt can interfere with proper operation so with a system that detects soiling of the measuring chamber, it's indicated by a LED and requires service personnel intervention. Such a solution significantly improves system efficiency and fire safety.


DCP-100 Detector
-
A1R point heat detector
-
The point heat detector is designed to detect a rapid rise in temperature or cases of exceeding the limit temperature as a result of a developing fire.
-
-
A1R heat detector in conformance with EN54-5
-
simple installation of the detector at the base of DB-100
-
possibility of connecting an external status indicator
DRP-100 Detector
-
Point optical smoke detector
-
The point smoke detector is designed to detect visible smoke which is present when a fire is developing.
-
-
unique Swirl chamber accelerates smoke detection
-
test fires detected: TF-2 to TF-5 acc. to EN54-7 and TF-1 and TF-8 acc. to ISO/TS 7240-9:2006
-
stainless-steel precision filter
-
failure signalling – contamination of measuring chamber
-
simple detector installation at the base of DB-100
-
possibility of connecting an external status indicator

CSP 100 or 200 Series?


Benefits
The SSP Fire Detection and Alarm System (FDAS) meets the strict EN54 safety standards. It is managed by CSP fire alarm control panels (FACP) with an easy to read front panel for convenient system operation.
The FACPs have two non-volatile memories. One collects up to 8999 events (and alarms), while the other stores up to 9999 alarms only. These data will help you, for example, to identify errors when operating the system. They can be exported to common file formats (e.g. CSV).
The system can also be operated via the so-called panels (located up to 1 km away from the FACP). These devices, installed e.g. in the security building, provide access to all functions of the system and its current status data. The latter can also be tracked remotely - through the Java Web Start application. When the control panel works with the CSP-ETH Ethernet module, information is available in the Virtual PSP panel visible in the web browser.
Dust and dirt can interfere with proper operation of smoke detectors and smoke / heat detectors and can trigger false alarms. That is why SATEL detectors are equipped with a system that detects soiling of the measuring chamber. Soiling is indicated by a LED and requires service personnel intervention. Such a solution significantly improves system efficiency and fire safety.